On March 21, 2011, the EPA published three rules regarding air emissions standards in the Federal Register. Two of the three rules pertain to boilers and are specifically designed to reduce emissions of air pollutants. The two rules are: Major Source Rule (also known as Boiler MACT or BMACT), designed to reduce boiler and process heater emissions at large sources of air toxics; and the Area Source Rule, created to reduce boiler emissions at small sources of air toxics.
Boilers

 

The EPA is reconsidering parts of the Major Source and Area Source Rules. While it is carrying out the formal reconsideration process, the EPA announced in May 2011 that it would delay the implementation of the Major Source Rule until further notice. However, the compliance requirements of the Area Source Rule, which include the majority of boilers in the United States, are in effect while the EPA is reconsidering this rule.

 

DETERMINING THE APPLICABLE RULE

Area source facilities are subject to the Area Source Rule, and major source facilities will be subject to the Major Source Rule when it goes into effect. The EPA defines a major source facility as one that emits 10 or more tons per year of any single air toxic or 25 tons or more per year of any combination of air toxics. A comprehensive list of the regulated air toxics can be found on the EPA website at www.epa.gov. Methods for calculating a facility’s emissions are detailed in the “Preferred and Alternative Methods for Estimating Air Emissions from Boilers” guide, available on the EPA site.

Typically, the majority of major source boilers and process heaters are located at very large industrial facilities, such as refineries, chemical and large manufacturing plants, and large institutional facilities such as universities.

Any facility that is not a major source is classified as an area source. Most boilers covered by the Area Source Rule are located at commercial and institutional facilities, with a smaller number in the industrial sector. Commercial boilers include those found in stores/malls, laundries, apartments, restaurants, and hotels/motels. Institutional boilers are found in many locations, including medical centers, educational and religious facilities, amusement parks, and municipal buildings. Many manufacturing facilities are also area sources.

 

MEETING COMPLIANCE REQUIREMENTS

Facilities subject to the Area Source Rule should have submitted an initial notification of applicability form by September 17, 2011. If the form was not submitted, complete it and turn it in as soon as possible. A copy of the form is available at www.cleaverbrooks.com/epa.

Additional compliance requirements can range from fuel metering and regular tune-ups to emissions monitoring. Facilities also must maintain records and file periodic reports to demonstrate compliance. The extent of actions and number of reports to be filed varies depending upon the following boiler criteria: fuel type, size, and age.

 

All Area Sources can be classified as one of the following fuel subcategories:

•          Biomass — any boiler that burns at least 15% biomass on an annual heat input basis;

•          Coal — any boiler that burns any solid fossil fuel and no more than 15% biomass on an annual heat input basis;

•          Oil — any boiler that burns any liquid fuel and is not in either the biomass or coal subcategories; and

•          Gas-fired — any boiler that burns gaseous fuels, including: natural gas, process gas, landfill gas, coal-derived gas, refinery gas, hydrogen, or biogas, not combined with any solid fuels. To maintain status as a gas-fired boiler, periodic burning of a liquid fuel cannot exceed a combined total of 48 hours during any calendar year.

 

Boiler size, as it relates to the Area Source Rule, is expressed in terms of rated design heat input capacity and is measured in million British thermal units per hour, or MMBtuh.

A boiler is considered an existing source if construction or reconstruction began on or before June 4, 2010. A boiler is considered a new source if construction or reconstruction began after June 4, 2010, and the applicability criteria was met when construction started, or the boiler switched from firing natural gas fuel to a solid fossil fuel, biomass, or liquid fuel after June 4, 2010.

The following are examples of Area Source Rule boiler requirements:

 

•          For a large, existing, oil-burning boiler, the fuel must be metered, a tune-up needs to be conducted every other year, and a one-time energy assessment completed.

•          For a large, existing coal-fired boiler, the fuel has to be metered and it must meet mercury (Hg), carbon monoxide (CO) and particulate emissions limits.

Cleaver-Brooks has set up an educational website at www.cleaverbrooks.com/epa to make it easier for facility managers to understand the EPA’s new rules for boilers. On the site, managers can find out which rules and work practices apply to their facility, and they can download the necessary forms for completion. For information about fuel metering options or other compliance solutions, contact an authorized Cleaver-Brooks representative.  TB

 

Goggins is director of marketing communications and development for Cleaver-Brooks. Cleaver-Brooks is a world-renowned provider of boiler room products and systems that helps customers and the industry reduce energy usage, cost, and environmental impact. As the pioneer of packaged firetube and watertube boilers, Cleaver-Brooks is the only manufacturer to offer an entirely integrated boiler room solution for any size application. Visit www.cleaverbrooks.com for
more information.

You must login or register in order to post a comment.

Multimedia

Videos

Image Galleries

ES Gallery: Snapshots & Systems

Check out highlights from projects featured in our magazine this year!

Engineered Systems Magazine

ES October 2014 cover

2014 October

Check out the October 2014 issue of Engineered Systems, with features on economizers, pump operations, and much more!

Table Of Contents Subscribe

System Design

Based on your experience and knowledge level, are you currently comfortable designing or maintaining a system incorporating VRF or radiant ceiling panels?
View Results Poll Archive

THE ENGINEERED SYSTEMS STORE

The_Green_Energy_Management
The Green Energy Management Book

Learn from our experts how to evaluate job opportunities, market your services, sell a Walk-through Survey, target areas for an Energy Audit, calculate energy savings, do retrofit work, and win continuing contracts for retrofit work.

More Products

Clear Seas Research

Clear Seas Research ImageWith access to over one million professionals and more than 60 industry-specific publications,Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

Tomorrow's Environment Podcast

This series from longtime columnist and chronic forward-thinker Howard McKew covers a lot of ground -- from retrocommissioning to systems training, on toward checklists for drawings and tips for meeting minutes. Click HERE to be taken to the podcast page!

STAY CONNECTED

new Facebook icon Twitter icon YouTube iconLinkedIn icon  Google+